efisiensi tinggi frp Cone tipe industri knalpot kipas ledakan buktina témbok ventilating fans keur paling lingkungan
1260-Modél 50 "(inci) FRP Ledakan Buktina Industrial Exhaust Fan Ventilating Tembok
Daptar eusi
1. Naon FRP Explosion Buktina Industrial Exhaust Fan?
2. Naon komponén penting tina FRP Ledakan Buktina Industrial Exhaust Fan? Pigura, Shell, Motor, agul, Louver jeung suku cadang.
3. Kumaha ukuran sareng jinis kipas knalpot industri? Model MS-680, MS-850, MS-1060, MS-1260, MS-1460
4. Naon Tujuan Ledakan Buktina Industrial Exhaust Fan Pikeun Tembok Ventilating System?
5. Kumaha Cara Milih Fans Anu Katuhu Pikeun Sistem Ventilasi Industri Unggas?
1. Naon FRP Explosion Buktina Industrial Exhaust Fan?
Prosés Manufaktur Produk: FRP Ledakan Buktina Industrial Exhaust Fan nujul kana kipas dijieunna tina serat kaca bertulang plastik (FRP). Penampilan sarta ukuran sarta kipas baja persis sarua, tapi cangkang jeung impeller dijieunna tina baja kaca, Marshine boga ciri lalawanan korosi, asam sarta lalawanan alkali, mangrupakeun jenis kipas anti korosi.
Bahan produk: FRP Ledakan Buktina Industrial Exhaust Fan cangkang nyaéta 10mm ketebalan.Eta bakal pisan stabilitas jeung durability.Jeung kipas knalpot ketebalan wates 18mm pikeun durability comparably luhur sarta instalasi kakuatan.Marshine Fan impeller adopts frp SMC impeller, kakuatan bending teu kurang ti 196 Mpa, unggal bagian adopts lemes kaleuleuwihan, penampilan lemes, teu retakan, sela, burrs na defects sejen, pangaruh sakabéh alus, kipas ngabogaan aerodynamics lumrah, hawa badag. volume, noise low, efisiensi tinggi, lalawanan korosi.
2. Naon komponén penting tina FRP Explosion Buktina Industrial Exhaust Fan?
FRP Explosion Proof Industrial Exhaust Fan mangrupikeun jinis alat ventilasi énggal anu didamel tina bahan FRP.Kusabab pigura luar kipas dijieunna tina FRP anti korosi, nu FRP kipas tekanan négatip bisa tukeur hawa ngaliwatan tekanan négatip, nu bisa ngahontal tujuan sirkulasi hawa, ventilasi jeung cooling, ku kituna disebut oge FRP kipas tekanan négatip.
Cangkang Rangka Kipas:
cangkang kipas dijieunna tina serat kaca bertulang plastik (FRP) béda ti kipas biasa.Cangkang kipas Marshine sareng impeller didamel tina plastik anu diperkuat serat gelas.Karakteristik pangbadagna nyaéta résistansi korosi sareng résistansi asam sareng alkali.
Louver atanapi jepret:
Jepret PVC: Ngagunakeun prinsip hilir hawa, jepret ieu hampang sareng nunjukkeun sipat antioksidan, beurat hampang sareng tahan ka distorsi.éta tiasa muka sareng nutup gancang anu nyegah aliran balik hawa.
Bilah kipas:
Ngadopsi serat kaca bertulang kipas sabeulah palastik, euweuh lebu, bentukna sabeulah husus
Mastikeun volume hawa badag, euweuh deformasi, euweuh narekahan
Motor kawat tambaga murni.
Motor ngadopsi motor tambaga murni standar nasional, laju gancang,
kakuatan badag, boga alat panyalindungan kakuatan leungitna, kelas panyalindungan IP55, insulasi kelas F
Kentel Stent:
kakuatan tinggi, noise low, awét.
Bantalan barang kualitas luhur.
Diimpor Bearing:
Laju alus, noise low, teu gampang karat Kakuatan tinggi, teu gampang mun teu ngagem
3. Kumaha ukuran sareng jinis kipas knalpot industri?
Item No. | Diménsi (mm) | Daya (W) | Tiupan hawa | Tegangan / Frékuénsi | Geuning | Laju Rotasi | Beurat bersih |
560# | 560x560x440mm(22"x22"x17") | 250W (3p) | 10000 m³ / h 5900CFM | 380V/50Hz (disesuaikeun) | ≤45db | 950 rpm | 35 kg |
680# | 680x680x450mm(26"x26"x18") | 250W (5p) | 12000 m³ / h 7200CFM | 380V/50Hz (disesuaikeun) | ≤45db | 820 rpm | 40 kg |
850# | 850x850x480mm(33"x33"x19") | 370W (8P) | 17000m³ / h 10000CFM | 380V/50Hz (disesuaikeun) | ≤53db | 620 rpm | 45 kg |
1060# | 1060x1060x550mm(42"x42"x22") | 550W (10P) | 28000m³ / h 16600CFM | 380V/50Hz (disesuaikeun) | ≤55db | 560 rpm | 50 kg |
1260# | 1260x1260x560mm(50"x50"x22") | 750W (10P) | 37000m³ / h 22000CFM | 380V/50Hz (disesuaikeun) | ≤65db | 520 rpm | 65 kg |
1460# | 1460x1460x580mm(57"x57"x23") | 1.1KW(10P) | 45000m³ / h 26500CFM | 380V/50Hz (disesuaikeun) | ≤65db | 450 rpm | 75 kg |
4. Naon Tujuan Ledakan Buktina Industrial Exhaust Fan Pikeun Tembok Ventilating System?
Fitur tina FRP Explosion Proof Industrial Exhaust Fan:
Sakabeh kipas Marshine adopts design CAD / CAM, nu boga ciri biaya investasi low, volume hawa badag, noise low, konsumsi énergi leutik, operasi stabil, hirup panjang tur efisiensi tinggi.
Louver otomatis naék sareng nutup janten tahan lebu, tahan cai sareng éndah.Ieu téh mangrupa pilihan pangalusna pikeun cooling jeung ventilasi di bengkel modern.Perlindungan lingkungan, énergi - nyimpen kipas tekanan négatip bakal janten aliran utama pasar alat pendingin ventilasi.
Peran FRP Explosion Proof Industrial Exhaust Fan:
1, Pikeun ventilasi: dipasang di luar jandela bengkel, umumna milih outlet hawa, ventilasi kaluar, kaluar tina gas bau aneh;tutuwuhan kimia umum jeung aplikasi sejenna leuwih.
2. Paké kalawan curtain baseuh: dipaké pikeun usum panas panas, euweuh urusan sabaraha panas workshop anjeun, curtain baseuh - sistem kipas tekanan négatip bisa nyieun hawa workshop anjeun turun ka ngeunaan 30 ℃, sarta aya kalembaban tangtu. .
5. Kumaha Cara Milih Fans Anu Katuhu Pikeun Sistem Ventilasi Industri Unggas?
Kipas Ventilasi Sisi:
Imah jangjangan biasana dilengkepan kipas samping (kipas leutik) pikeun tujuan dasar pikeun ngajaga volume ventilasi minimum di jerona.
Jumlah kipas samping = volume ventilasi minimum dina beurat maksimum domba di imah unggas ÷ volume ventilasi kipas
Contona, pikeun ngawangun imah unggas anu ngandung 30.000 hayam, upami beurat rata-rata maksimal masing-masing 3 kg, maka jumlah kipas samping = 30.000 × 3 kg / masing-masing × 0,0155 meter kubik / menit.kg (koefisien ventilasi minimum) ÷ volume ventilasi kipas
Nyandak kana akun leungitna volume kipas Marshine disababkeun ku rupa-rupa alesan, kituna, 1-2 fans deui kudu dipasang dina praktekna sabenerna.
kipas ventilasi longitudinal:
Jumlah kipas longitudinal anu dipasang aya hubunganana sareng suhu anu luhur dina usum panas.Dina usum panas panas, pangaruh cooling hawa bisa dihontal ku cara ningkatkeun laju angin di imah jangjangan, kukituna ngurangan hawa wijaksana tina barung.
Jumlah kipas longitudinal = aréa cross-sectional imah ternak × laju angin nu dipikahoyong ÷ volume ventilasi kipas (kusabab béda régional, suhu jeung kalembaban dina usum panas di unggal wewengkon béda, jadi laju angin nu dipikahoyong. variasina ogé)
Contona, lamun imah unggas panjangna 100 méter, rubak 14 méter, sarta témbok samping luhurna 2,5 méter, hateupna 4 méter, sarta laju angin nu dipikahoyong 2,5 méter per detik, mangka jumlah kipas longitudinal = 14. méter × {2,5 méter + (4 méter- 2,5 méter) ÷ 2} × 2,5 méter/detik × 60 detik/menit ÷ volume ventilasi kipas